Most homes have a smoke alarm. Far fewer have the right alarms, in the right places, connected to each other so that a fire in the kitchen wakes someone asleep upstairs. The rules around fire detection in homes are more specific than people expect, and they’ve tightened over the years.

Here’s what the different alarm types do, where they belong, and what’s actually required.

Smoke alarm or heat detector?

Smoke alarms detect smoke particles and are the right choice for hallways, landings and living rooms.

Heat detectors respond to a rapid rise in temperature rather than smoke, which makes them the right choice for kitchens and garages, where a smoke alarm would go off every time you made toast.

Carbon monoxide alarms are a separate thing altogether and belong in any room with a fuel-burning appliance such as a gas boiler, a wood burner or an open fire.

Where they should go

In a privately owned home none of this is a legal requirement, but it would be a strange thing to skip. As a minimum, there should be a smoke alarm on every storey of the home, normally in the hallway and on each landing, positioned on the ceiling away from corners and light fittings. Kitchens get a heat detector. Rooms where a fire is more likely to start, such as a living room with a wood burner, benefit from their own detection. The grade and category of system a home needs depends on the property, and new-build and converted properties have specific requirements under the building regulations.

Why interlinked and mains-powered matters

A battery alarm in the hallway is better than nothing. But if a fire starts in the kitchen at night, a single alarm downstairs may not wake anyone upstairs, and battery alarms have a habit of being taken down when they chirp. Mains-powered alarms with battery back-up, interlinked so that when one sounds they all sound, are the standard for new homes and the sensible upgrade for existing ones. Interlinking can be wired or wireless, so it doesn’t necessarily mean chasing cables through finished walls.

Homeowners

For an existing owner-occupied home there’s no legal requirement to have a particular alarm system, but any electrical work of substance, such as a rewire or a major renovation, is expected to bring the fire detection up to current standards, and it’s the obvious time to do it. Mains alarms are notifiable electrical work if new circuits are involved, and should be installed and certified by a registered electrician.

Landlords

Landlords in England must ensure there’s at least one working smoke alarm on each storey used as living accommodation and a carbon monoxide alarm in any room with a fixed combustion appliance, and must check they work at the start of every tenancy. We’ve covered the wider picture in our guide to landlord electrical safety.

Maintenance

Test alarms monthly. Replace batteries in back-up alarms as recommended. Alarms themselves have a limited life and carry a replace-by date on the back, so check it; a ten-year-old alarm may not be doing anything at all.

Getting them fitted

A mains-powered, interlinked system is a small job in the scheme of things and one that’s often added alongside a consumer unit upgrade or an Electrical Installation Condition Report, when the electrician is already on site and can see how the house is laid out.

DW Electrical Solutions installs smoke and heat alarm systems across Hampshire, from Portsmouth and Havant to Winchester and Basingstoke. NAPIT approved. Get in touch to discuss your project.

Smoke Alarms and Heat Detectors: The Rules

November 18, 2025EICR