Garden rooms have gone from a luxury to a normal part of how Hampshire homes work: an office at the end of the lawn, a gym, a studio, a workshop. Whatever the building is for, it’s only as useful as the electrical supply feeding it, and that supply is the part most often left to the last minute.

Here’s how power gets to an outbuilding properly, what to decide before the base is laid, and what separates a safe installation from an extension lead through the window.

Start before the base goes down

The cable from the house to the garden room runs underground, in a trench at a suitable depth, and the best time to dig that trench is when the garden is already being dug up for the base. Get the electrician involved when the garden room supplier gives you a date, not after the building is up. The same trench can carry data cabling for a reliable internet connection, which for a garden office matters as much as the power.

What a proper supply looks like

An outbuilding supply is a small electrical installation in its own right:

  • A dedicated circuit from the house consumer unit, with its own protective device and RCD protection.
  • Armoured cable (SWA) from the house to the garden room, routed and protected properly. The steel armour is what protects the cable, so it doesn’t rely on being buried deep.
  • A consumer unit in the garden room. We always recommend one, so the sockets, lighting and any heating have their own circuits, separate from the house. If something trips in the garden room, it trips there, and the house carries on undisturbed.
  • Correct earthing arrangements, which depend on how the house is supplied and are one of the more technical parts of the job.

Everything is tested and certified, and because the work involves a new circuit it’s notifiable under the building regulations. DW Electrical Solutions is NAPIT approved, so that notification is handled as part of the installation.

How much power will it need?

That depends entirely on what the building is for. A home office with a laptop, a lamp and a small heater is modest. A workshop with machinery, a gym with a treadmill, or a studio with electric heating and a kettle is a different proposition, and the cable and protective devices need sizing for the real load rather than a guess. Think honestly about heating: electric heating in an uninsulated garden room in January is where the demand really sits.

If the house’s consumer unit has no spare ways or is older, the garden room supply is often the moment it gets upgraded.

Inside the garden room

Plan sockets generously; garden rooms always end up with more in them than intended. Think about lighting on a dimmer, an outside light by the door, and whether you want a socket outside for garden tools. If the building will be used in the evening, decent path and garden lighting between the house and the garden room is a small addition that makes a big difference. We’ve covered outdoor lighting more broadly in our guide to making the most of your garden safely.

What not to do

An extension lead through a window is not a supply, and neither is a length of ordinary flex clipped to the fence. Both are common, both fail in the wet, and both are the sort of thing an Electrical Installation Condition Report will pick up when you come to sell. Done properly, an outbuilding supply is a one-time job that lasts as long as the building.

DW Electrical Solutions installs garden room and outbuilding electrics across Hampshire, from Emsworth and Havant to Winchester and Eastleigh. Get in touch to discuss your project.