Water and electricity are not friends, which is why the bathroom is the one room in the house where the wiring regulations get very specific about what can go where. Get it right at the planning stage and you’ll have a bathroom that’s safe, well lit and properly ventilated. Get it wrong and it’s tiles up and start again.
Here’s what homeowners need to know before the bathroom fitter arrives.
Why bathrooms are different
Bathroom electrics are governed by a zoning system. The area in and around the bath or shower is divided into zones based on how close it is to water, and each zone limits the type of electrical equipment allowed and how well protected it must be against moisture. On top of that, all circuits serving a bathroom need RCD protection, which is what keeps the room safe if anything does go wrong.
None of that is something to work out from a forum post. It’s the reason new circuits and alterations to existing circuits in a bathroom are notifiable under the building regulations and should be done by a registered electrician. A straightforward like-for-like replacement of a fitting isn’t notifiable, but anything beyond that is.
Electric showers
An electric shower is one of the heaviest single loads in a home. It needs its own dedicated circuit from the consumer unit, cable sized to the shower’s rating, a suitable isolator switch and RCD protection. Upgrading to a more powerful shower is not simply a case of swapping the unit on the wall; the cable and protective device behind it often need upgrading too. We’re called out regularly to isolator switches that have overheated and melted because the cable feeding them was too small for the kilowatt rating of the shower that was fitted. If your consumer unit is older, a new shower circuit is often the prompt to replace it.
Lighting
Bathroom light fittings need an appropriate IP rating for their zone, which is why you’ll see “bathroom rated” downlights and fittings sold specifically for the purpose. Beyond compliance, think about what the light is for: bright, even light for the mirror, softer lighting for a bath, and whether you want the two on separate switches. Illuminated and heated mirrors are popular and need a fused connection planned in.
Switches inside the bathroom are generally pull-cords; a standard wall switch belongs outside the door. Sockets are not permitted except shaver sockets of the correct type, and even those have placement rules.
Extractor fans
A bathroom without adequate ventilation grows mould, and building regulations expect mechanical extraction where there’s no openable window, and in practice recommend it even where there is. Fans can run from the lighting circuit with an overrun timer, or from a humidity sensor so they only run when needed. Position matters: near the source of steam, away from the incoming air.
Heated towel rails and underfloor heating
Electric towel rails and electric underfloor heating are both straightforward to include if planned early. Both need a fused connection and RCD protection, and underfloor heating in particular has to go in before the floor, which sounds obvious until the tiler is booked for Monday.
Plan it before the tiler arrives
Every one of these decisions is easy while the walls are open and expensive afterwards. If the bathroom is part of a wider renovation, it’s worth reading our guide to why full or partial rewires matter, because a new bathroom on old wiring is a common point at which the rest of the installation gets looked at.